Load test results

Measured capacity of a single xprem instance serving the expo-updates protocol.

File Contents
2026-08-01-summary.json Configuration, traffic model, per-phase results, limits
2026-08-01-timeseries.csv Every metric over time, long format
../loadtest.js The k6 script that produced them
../grafana-dashboard.json Dashboard used to watch the runs

The CSV is one point per row, ready for any charting tool:

t_seconds,source,metric,scenario,value

t_seconds is seconds since the run started. source is k6, server or database. scenario is set for the k6 latency and throughput series (fleet, probe, push_storm) and empty otherwise.

Run of 1 August 2026

Configuration. One EC2 c6g.medium (1 vCPU, 2 GiB) running the server in Docker, an RDS PostgreSQL db.t4g.small (2 vCPU, 2 GiB), Google Cloud Storage for update bundles, and a separate c7g.xlarge in the same VPC generating load with k6. Code signing and device telemetry both enabled. No load balancer: the generator talks plain HTTP to the private address, since TLS is terminated upstream in a real deployment.

Method. Requests are real expo-updates polls from a fixed pool of 100,000 devices with stable identifiers, every response RSA-signed. The load is applied in an open model: the target rate is imposed whether or not the server keeps up, so queueing shows as latency instead of being hidden by a slower client. Three phases: the peak-hour traffic of real fleets, a slow ramp to locate the saturation point, and a rollout pushed to the entire fleet.

Results. 294,372 requests, zero errors, zero dropped iterations.

Phase Rate mean p95 p99
fleet 230 req/s 1.46 ms 1.58 ms 2.35 ms
probe 650 req/s 1.02 ms 1.39 ms 2.28 ms
push_storm 938 req/s 3.15 ms 20.5 ms 55.2 ms

All three statistics share one window: the phase minus the first 60 seconds of the run, which are the cold start (empty caches, empty connection pool, first signature computed). Percentiles are the peak reached in that window, the mean is its average. The cold start itself peaks at 98 ms and is reported separately in the summary.

The saturation knee was not reached at the highest rate tested. The server peaked at 87.8% CPU during the storm; the database peaked at 27% CPU and accrued CPU credits over the run rather than depleting them.

Read 2026-08-01-summary.json for the full numbers, and its limits array for what this run does not establish.

Reproducing

k6 run -o experimental-prometheus-rw \
  --tag testid=<run-name> \
  -e BASE_URL=http://<server>:3000 \
  -e APP_ID=<app-id> \
  -e IOS_UPDATE_ID=<ios-manifest-id> \
  -e ANDROID_UPDATE_ID=<android-manifest-id> \
  test/load/loadtest.js

Every published run reports dropped_iterations. A run whose generator could not inject the requested load is not a measurement of the server.